MegaCli64 Cheat Sheet
|
Alteeve Wiki :: MegaCli64 Cheat Sheet |
| Note: All content here is "©2014 LSI Corporation. All rights reserved". This copy is made of reference only and no claim is made by Alteeve's Niche! to any of the referenced material. |
This page is a nearly direct copy of LSI/Avago reference page, as of July 26, 2014, for the MegaCli Linux command line tool.
This copy was made for two reasons;
- The original article was formatted in such a way that the content was hard to read.
- A copy of the content was desired in case of interruption in LSI/Avago's website.
General Commands
| Command | Syntax |
|---|---|
| View Version | MegaCli64 v |
| Help | MegaCli64 help|h|? |
Set Adapter Properties
| Command | Syntax | Example |
|---|---|---|
| Cache Flush Interval | MegaCli64 AdpSetProp {CacheFlushInterval val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp CacheFlushInterval 2 a0 |
| Rebuild Rate | MegaCli64 AdpSetProp {RebuildRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp RebuildRate 75 a0 |
| Patrol Read Rate | MegaCli64 AdpSetProp {PatrolReadRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp PatrolReadRate 38 a0 |
| BGI (BackGround Interval) Rate | MegaCli64 AdpSetProp {BgiRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp BgiRate 92 a0 |
| CC (Consistency Check) Rate | MegaCli64 AdpSetProp {CCRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp CCRate 23 a0 |
| Reconstruction Rate | MegaCli64 AdpSetProp {ReconRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp ReconRate 15 a0 |
| Spinup Drive Count | MegaCli64 AdpSetProp {SpinupDriveCount val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp SpinupDriveCount 2 a0 |
| Spinup Delay | MegaCli64 AdpSetProp {SpinupDelay val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp SpinupDelay 10 a0 |
| Coercion Mode | MegaCli64 AdpSetProp {CoercionMode val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp CoercionMode 0 a0 |
| Predictive Failure Poll Interval | MegaCli64 AdpSetProp {PredFailPollInterval val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp PredFailPollInterval 20 a0 |
| Battery Warning Enable/Disable | MegaCli64 AdpSetProp {BatWarnDsbl val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp BatWarnDsbl 0 a0 |
| ECC Bucket Size | MegaCli64 AdpSetProp {EccBucketSize val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp EccBucketSize 128 a0 |
| ECC Bucket Leak Rate | MegaCli64 AdpSetProp {EccBucketLeakRate val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp EccBucketLeakRate 64 a0 |
| Abort Check Consistency on Error | MegaCli64 AdpSetProp {AbortCCOnError val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp AbortCCOnError 0 a0 |
| Enable SMART Copyback | MegaCli64 AdpSetProp {SMARTCpyBkEnbl val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp SMARTCpyBkEnbl 0 a0 |
| Enable SSD SMART Copyback | MegaCli64 AdpSetProp {SSDSMARTCpyBkEnbl val} aN|a0,1,2|aALL | MegaCli64 AdpSetProp SSDSMARTCpyBkEnble 0 a0 |
| Enable NCQ | MegaCli64 AdpSetProp {NCQEnbl} aN|a0,1,2|aALL | MegaCli64 AdpSetProp NCQEnbl a0 |
| Disable NCQ | MegaCli64 AdpSetProp {NCQDsbl} aN|a0,1,2|aALL | MegaCli64 AdpSetProp NCQDsbl a0 |
Alarm Control
| Command | Syntax | Example |
|---|---|---|
| Alarm Enable | MegaCli64 AdpSetProp AlarmEnbl aN|a0,1,2|aALL | MegaCli64 AdpSetProp AlarmEnbl a0 |
| Alarm Disable | MegaCli64 AdpSetProp AlarmDsbl aN|a0,1,2|aALL | MegaCli64 AdpSetProp AlarmDsbl a0 |
| Alarm Silence | MegaCli64 AdpSetProp AlarmSilence aN|a0,1,2|aALL | MegaCli64 AdpSetProp NCQDsbl a0 |
View Adapter Properties
| Command | Syntax | Example |
|---|---|---|
| View number of adapters | MegaCli64 adpcount | MegaCli64 adpcount |
| Cache Flush Interval | MegaCli64 AdpGetProp CacheFlushInterval aN|a0,1,2|aALL | MegaCli64 AdpGetProp CacheFlushInterval a0 |
| Rebuild Rate | MegaCli64 AdpGetProp RebuildRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp RebuildRate a0 |
| Patrol Read Rate | MegaCli64 AdpGetProp PatrolReadRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp PatrolReadRate a0 |
| BGI (BackGround Interval) Rate | MegaCli64 AdpGetProp BgiRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp BgiRate a0 |
| CC (Consistency Check) Rate | MegaCli64 AdpGetProp CCRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp CCRate a0 |
| Reconstruction Rate | MegaCli64 AdpGetProp ReconRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp ReconRate a0 |
| Spinup Drive Count | MegaCli64 AdpGetProp SpinupDriveCount aN|a0,1,2|aALL | MegaCli64 AdpGetProp SpinupDriveCount a0 |
| Spinup Delay | MegaCli64 AdpGetProp SpinupDelay aN|a0,1,2|aALL | MegaCli64 AdpGetProp SpinupDelay a0 |
| Coercion Mode | MegaCli64 AdpGetProp CoercionMode aN|a0,1,2|aALL | MegaCli64 AdpGetProp CoercionMode a0 |
| Predictive Failure Poll Interval | MegaCli64 AdpGetProp PredFailPollInterval aN|a0,1,2|aALL | MegaCli64 AdpGetProp PredFailPollInterval a0 |
| Battery Warning Enable/Disable | MegaCli64 AdpGetProp BatWarnDsbl aN|a0,1,2|aALL | MegaCli64 AdpGetProp BatWarnDsbl a0 |
| ECC Bucket Size | MegaCli64 AdpGetProp EccBucketSize aN|a0,1,2|aALL | MegaCli64 AdpGetProp EccBucketSize a0 |
| ECC Bucket Leak Rate | MegaCli64 AdpGetProp EccBucketLeakRate aN|a0,1,2|aALL | MegaCli64 AdpGetProp EccBucketLeakRate a0 |
| Abort Check Consistency on Error (CC) | MegaCli64 AdpGetProp AbortCCOnError aN|a0,1,2|aALL | MegaCli64 AdpGetProp AbortCCOnError a0 |
| Alarm Status (Enabled/Disabled/Silenced) | MegaCli64 AdpGetProp AlarmDsply aN|a0,1,2|aALL | MegaCli64 AdpGetProp AlarmDsply a0 |
| All Adapter Information | MegaCli64 AdpAllInfo aN|a0,1,2|aALL | MegaCli64 AdpAllInfo a0 |
| Get Adapter Time | MegaCli64 AdpGetTime aN|a0,1,2|aALL | MegaCli64 AdpGetTime a0 |
| Set Adapter Time | MegaCli64 AdpSetTime yyyymmdd hh:mm:ss aN | MegaCli64 AdpSetTime 20071210 9:33:00 a0 |
| Adapter Set Verify | MegaCli64 AdpSetTime yyyymmdd hh:mm:ss aN | MegaCli64 AdpSetTime 20071210 9:33:00 a0 |
Adapter BIOS State / Boot Options
| Command | Syntax | Example |
|---|---|---|
| Enable BIOS | MegaCli64 AdpBIOS Enbl aN|a0,1,2|aALL | MegaCli64 AdpBIOS Enbl a0 |
| Disable BIOS | MegaCli64 AdpBIOS Dsbl aN|a0,1,2|aALL | MegaCli64 AdpBIOS Dsbl a0 |
| Set BIOS to Stop on Error | MegaCli64 AdpBIOS SOE aN|a0,1,2|aALL | MegaCli64 AdpBIOS SOE a0 |
| Set BIOS to Bypass Error | MegaCli64 AdpBIOS BE aN|a0,1,2|aALL | MegaCli64 AdpBIOS BE a0 |
| Display BIOS State | MegaCli64 AdpBIOS Dsply aN|a0,1,2|aALL | MegaCli64 AdpBIOS Dsply a0 |
| Set Boot Drive | MegaCli64 AdpBootDrive {Set Lx} aN|a0,1,2|aALL | MegaCli64 AdpBIOS Dsply a0 |
| Display Boot Drive | MegaCli64 AdpBootDrive Get aN|a0,1,2|aALL | MegaCli64 AdpBootDrive Get a0 |
Adapter's Auto Rebuild Settings
| Note: This appears to be missing in the source document. |
Command Type
These sections are broken out into sections based on the 'Command Type' column in the source document. This breakout was done to preserve horizontal screen real-estate and to make index navigation more useful.
Server / System
| Command | Description | Syntax |
|---|---|---|
| Show system overview | Displays a summary of all the controllers that are present in the server. | MegaCli64 adpCount |
| Download firmware | CLI will attempt to download fw to all compatible controllers that supports the image. By default CLI with check signature and version. | MegaCli64 AdpFwFlash f filename [NoSigChk] [NoVerChk] aN|a0,1,2|aALL |
| Flash FW in Mode 0 with ROM file | Flashes the firmware in Mode 0 with the ROM file listed. For Mode 0 flash, the adapter number is not valid. | MegaCli64 AdpM0Flash f filename |
Patrol Read
| Any questions, feedback, advice, complaints or meanderings are welcome. | |||
| Alteeve's Niche! | Alteeve Enterprise Support | Community Support | |
| © 2025 Alteeve. Intelligent Availability® is a registered trademark of Alteeve's Niche! Inc. 1997-2025 | |||
| legal stuff: All info is provided "As-Is". Do not use anything here unless you are willing and able to take responsibility for your own actions. | |||