D-Link Notes: Difference between revisions
Jump to navigation
Jump to search
(Created page with "{{header}} Notes on setting up D-Link switches. = DGS-3120 Series = # Ensure you've updated the firmware to R2.00.010 or higher # System Configuration -> Stacking -> Stacking ...") |
No edit summary |
||
Line 1: | Line 1: | ||
{{header}} | {{header}} | ||
Notes on setting up D-Link switches. | Notes on setting up D-Link switches for high availabilty. | ||
= DGS-3120 Series = | = DGS-3120 Series = | ||
Confirmed | |||
# Ensure you've updated the firmware to R2.00.010 or higher | # Ensure you've updated the firmware to R2.00.010 or higher | ||
# System Configuration -> Stacking -> Stacking Mode Settings. Change 'Force Master Role' to 'Enabled'. | # System Configuration -> Stacking -> Stacking Mode Settings. Change 'Force Master Role' to 'Enabled'. | ||
Testing | |||
# System Configuration -> Port Configuration -> Port Settings. Set 'Flow Control' to 'Enabled' for all ports on both switches. | |||
## Confirm with <span class="code">dmesg |grep -i flow</span> and look for <span class="code">e1000e: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx</span>. If any interfaces show <span class="code">Flow Control: None</span>, it's not setup right. | |||
# Create VLANs for the bonds, 'untagged', disable advertisement (666 for SN, 71 for IFN, default/1 for BCN). | |||
# Setup Trunking; L2 Features -> Link Aggregation -> Port Trunking Settings. Set 'Type' to 'Static' and set switch 1 port X as the master. Create a trunk for each node's bond. | |||
{{footer}} | {{footer}} |
Revision as of 19:11, 9 July 2012
AN!Wiki :: D-Link Notes |
Notes on setting up D-Link switches for high availabilty.
DGS-3120 Series
Confirmed
- Ensure you've updated the firmware to R2.00.010 or higher
- System Configuration -> Stacking -> Stacking Mode Settings. Change 'Force Master Role' to 'Enabled'.
Testing
- System Configuration -> Port Configuration -> Port Settings. Set 'Flow Control' to 'Enabled' for all ports on both switches.
- Confirm with dmesg |grep -i flow and look for e1000e: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx. If any interfaces show Flow Control: None, it's not setup right.
- Create VLANs for the bonds, 'untagged', disable advertisement (666 for SN, 71 for IFN, default/1 for BCN).
- Setup Trunking; L2 Features -> Link Aggregation -> Port Trunking Settings. Set 'Type' to 'Static' and set switch 1 port X as the master. Create a trunk for each node's bond.
Any questions, feedback, advice, complaints or meanderings are welcome. | |||