= Managing Hot-Spares =  
= Managing Hot-Spares =  


In this final section, we will add a "Hot-Spare" drive to our node. A "Hot-Spare" is an unused drive that the control knows can be used to immediately replace a failed drive.  
In this final section, we will add a "Hot-Spare" drive to our node.


This is a popular option for people who want to return to a fully redundant state as soon after a failure as possible.
A "Hot-Spare" is an unused drive that the RAID controller knows can be used to immediately replace a failed drive. This is a popular option for people who want to return to a fully redundant state as soon after a failure as possible.


We will Configure a Hot-Spare, show how it replaces a failed drive, and show how to unmark a drive as a hot-spare, in case the Hot-Spare itself goes bad.
We will Configure a Hot-Spare, show how it replaces a failed drive, and show how to unmark a drive as a hot-spare, in case the Hot-Spare itself goes bad.
Line 257: Line 257:
== Creating a Hot-Spare ==
== Creating a Hot-Spare ==


Up until this point, we've had four physical disks in our system. Here, we've inserted a fifth healthy disk. The logical disk is <span class="code">Optimal</span>, so no default action was take. Likewise, no option to add the physical disk to a logical disk is presented.
[[Image:an-cdb_storage-control_25.png|thumb|800px|center|Newly inserted physical disk.]]
The one option that is presented, however, is '<span class="code">Make Hot-Spare</span>'.
[[Image:an-cdb_storage-control_26.png|thumb|800px|center|New physical disk with '<span class="code">Make Hot-Spare</span>' highlighted.]]
Once marked as a hot-spare, the disk will be automatically used to replace a physical drive, should one of an equal or smaller size fail.
[[Image:an-cdb_storage-control_27.png|thumb|800px|center|Physical disk now marked as a '<span class="code">Hot-Spare, Spun up</span>'.]]
Done!
Now any disk failure will recover as fast as technically possible.


== Example of a Hot-Spare Working ==
== Example of a Hot-Spare Working ==


As we saw earlier, there are many ways for a logical disk to degrade. The hot-spare will be used automatically as soon as the array is degraded, regardless of the cause.
For this reason, we'll simply remove a physical disk currently in the logical disk. We should see immediately that the hot-spare has entered the array and rebuild has begun.
I will remove physical disk '<span class="code">[252:6]</span>' from the array.
[[Image:an-cdb_storage-control_28.png|thumb|800px|center|Physical disk '<span class="code">[252:6]</span>' removed from the logical disk, former hot-spare physical disk '<span class="code">[252:5]</span>' already in the logical disk and rebuilding.]]
At this point, we could eject <span class="code">[252:6]</span> or spin it back up. I know it's healthy, so I will spin it up and mark it as a hot spare in preparation for the next section.


== Replacing a Failing Hot-Spare ==
== Replacing a Failing Hot-Spare ==
As we [[#Pre-Failure Drive Replacement|discussed earlier]], a drive may show signs of failing before it's actually failed. Of course, it could just as well die and get marked as <span class="code">Unconfigured(bad)</span> or vanish entirely.
In this case, we'll pretend the drive is predicted to fail.
To do this, simply click on '<span class="code">Unmark as Hot-Spare</span>'.
[[Image:an-cdb_storage-control_29.png|thumb|800px|center|Hot-spare physical disk's '<span class="code">Unmark as Hot-Spare</span>' highlighted.]]






{{footer}}
{{footer}}

Revision as of 22:54, 16 February 2014

 AN!Wiki :: How To :: Managing Drive Failures with AN!CDB

Note: At this time, only LSI-based controllers are supported. Please see this section of the AN!Cluster Tutorial 2 for required node configuration.

The AN!CDB dashboard supports basic drive management for nodes using LSI-based RAID controllers. This covers most all Fujitsu servers.

This guide will show you how to handle a few common storage management tasks easily and quickly.

Starting The Storage Manager

From the main AN!CDB page, under the "Cluster Nodes - Control window, click on the name of the node you wish to manage.

AN!CDB main page with node names as click-able items.

This will open a new tab (or window) showing the current configuration and state of the node's storage.

Storage Display Window

The storage display window shows your storage controller(s), their auxiliary power supply for write-back caching if installed, the logical disk(s) and each logical disk's constituent drives.

The auxiliary power and logical disks will be slightly indented under their parent controller.

The physical disks associates with a given logical disk are further indented, to show their association.

AN!CDB storage management page.

In this example, we have only one RAID controller, it has an auxiliary power pack and a single logical volume has been created.

The Logical volume is a RAID level 5 array with four physical disks.

Controlling the Physical Disk Identification ID Light

The first task we will explore is using identification lights to match a physical disk listing with a physical drive in a node.

If a drive fails completely, it's fault light will light up, making the failed drive easy to find. However, the AN!CDB alert system can notify us of pending failures. In these cases, the drive's fault light will not illuminate. So it becomes critical to identify the failing drive. Removing the wrong drive, when another drive is unhealthy, may well leave your node non-operational.

That's no fun.

Each physical drive will have a buttons labelled either Turn On or Turn Off, depending on the current state of the identification LED.

Illumination a Drive's ID Light

Let's illuminate!

We will identify the drive with the somewhat-cryptic name '252:0'.

Turning on the ID light for physical disk '252:0'.

The storage page will reload, indicating whether the command succeeded or not.

Physical disk '252:0' illuminated successfully.

If you now look at the front of your node, you should see one of the drives lit up.

Locating physical disk '252:0' on the node's front panel.

Most excellent.

Shutting off a Drive's ID Light

To turn the ID light off, simply click on the drive's Turn Off button.

Turning off the ID light for physical disk '252:0'.

As before, the success or failure will be reported.

Physical disk '252:0' ID light turned off successfully.

Refreshing The Storage Page

Warning: AN!CDB doesn't (yet) use a command key to prevent a request being sent again if a page is manually reloaded (ctrl + r, <f5>, etc). In most all cases, this is harmless as AN!CDB won't do something dangerous without verifying it is still safe to do so. Just the same, please always use the "reload" icon shown below.

After issuing a command to the storage manager, please do not use your browser's "refresh" function. It is always better to click on the reload icon.

Storage page "refresh" icon.

This will reload the page with the most up to date state of the storage in your node.

Storage page reloaded properly.

Failure and Recovery

There are many ways for hard drives to fail.

In this section, we're going to sort-of simulate four failures;

  1. Drive vanishes entirely
  2. Drive is failed but still online
  3. Good drive was ejected by accident, recovering
  4. Drive has not yet failed, but may soon

The first three are going to be sort of mashed together. We'll simply eject the drive while it's running, causing it to disappear and for the array to degrade. If this happened in real life, you would simply eject it and insert a new drive.

For the second case, we'll re-insert the ejected drive. The drive will be listed as failed ("Unconfigured(bad)"). We'll tell the controller to "spin down" the drive, making it safe to remove. If the real world, we would then eject it and install a new drive.

In the third case, we will again eject the drive, and then re-insert it. In this case, we won't spin down the drive, but instead mark it as healthy again.

Lastly, we will discuss predictive failure. In these cases, the drive has not failed yet, but confidence in the drive has been lost, so pre-failure replacement will be done.

Drive Vanishes Entirely

If a drive fails catastrophically, say the controller on the drive fails, you may find that the drive simply no longer appears in the list of physical disks under the logical disk.

Likewise, if the disk is physically ejected (by accident or otherwise), the same result will be seen.

The logical drive will list as 'Degraded', but none of the disks will show errors.

Degraded logical disk with no failed physical disks.

If you look under Logical Disk #X, you will see the number of physical disks in the logical disk beside the 'Number of Drives'. When you count the actual number of disks under the logical drive though, you will see the number of displayed disks is smaller.

In this situation, the best thing to do is locate the failed disk. The 'Failed' LED should be illuminated on bay with the failed or missing disk. If it is not lit, however, you may need to light up the ID LED on the remaining good disks and use a simple process of illimination to find the dead drive.

Once you know which disk is dead, remove it and install a replacement disk. So long as 'Restore Hot-Spare on Insert' is set to 'Yes', the drive should immediately be added to the logical disk and the rebuild process should start.

Inserting a Replacement Physical Disk

Replaced physical disk automatically added to logical disk and rebuild begun.

If the replacement drive doesn't automatically get added to the logical disk, you can add the new physical disk to the Degraded logical disk using the storage manager. The new disk will come up as 'Unconfigured(good), Spun Up'. Directly beneath that, you will see the option to 'Add to Logical Disk #X', where X is the logical disk number that is degraded.

Disk is 'Unconfigured(good), Spun Up' with option to add the physical disk to logical disk #0.

Click on that and the drive will be added to the logical disk. The rebuild process will start immediately.

Replacement physical disk manually added to logical disk #0, rebuild process started.

Drive is Failed but Still Online

If a drive has failed, but it's controller is still working, the drive should appear as 'Unconfigured(bad).

This will be one of the most common failures you will have to deal with.

Physical disk failed and marked as 'Unconfigured(bad)'.

You will generally have two options here.

  • Prepare it for removal
  • Try and make the drive "good" again

Preparing a Failed Disk for Removal

A failed disk may still be "spun up", meaning that it's platters are rotating. This places centripidal force on the drive, and moving the disk out of it's rotational axis before the drive has spun down completely could cause a head-crash. Further, the electrical connection to the drive will still be active, making it possible to cause a short when the drive is mechanically ejected, which could damager the drive's controller, the backplane or the RAID controller itself.

To avoid this risk, before a drive is removed, we must prepare it for removal. This will spin-down the disk and make it safe to eject with minimal risk of electrical shorts.

To prepare it for removal, you will click on 'Spin Down Disk'.

Failed physical disk with 'Spin Down Disk' option highlighted.
Note: In the example below, AN!CDB's first attempt to spin down the drive failed. So it attempted, successfully, to mark the disk as 'good' and then tried to spin it down a second time, which worked. Be sure to physically record the disk as failed!

Once spun down, the physical disk will be shown to be safe to remove.

Failed physical disk is ready to be removed.

Once you insert the new disk, it should automatically be added to the logical disk and the rebuild process should start. If it doesn't, please see "Inserting a Replacement Physical Disk" above.

Attempting to Recover a Failed Disk

Warning: If you do now know why the drive failed, replace it. Even if it appears to recover, it will likely fail again soon.

Depending on why the physical disk failed, it may be possible to mark is as "good" again. This should only be done in two cases;

  • You know why the disk was flagged as failed and you trust it is actually healthy
  • To try and restore redundancy to the logical disk while you wait for the replacement disk to arrive

Underneath the 'Unconfigured(good), Spun Up' disk state will be the option 'Make good'.

Failed disk with 'Make Good' option highlighted.

If this works, the disk state will change to 'Unconfigured(good), Spun Up'. Below this, one of two options will be available;

Physical disk marked good.
  • If (one of) the logical disk(s) are defraded, Add to Logical Disk #X will be available.
  • If (all) the logical disk(s) are 'Optimal', you will be able to mark the disk as a 'Hpt Spare'.

In this section, we will add it to a degraded logical disk. Managing hot-spares is covered further below. Do note though; If you mark a disk as a hot-spare when a logical disk is degraded, it will automatically be added to that degraded logical disk and rebuild will begin.

If there are multiple degraded logical disks, you will see multiple 'Add to Logical Disk #X' options, one for each degraded logical disk. In our case, there is just one logical disk, so there is just one option.

Recovered physical disk's Add to Logical Disk #0 button highlighted.

Once you click on 'Add to Logical Disk #X', the physical disk will appear under the logical disk and rebuild will begin automatically.

Recovered physical disk's back in the logical disk and rebuild has begun.

Done.

Recovering from Accidental Ejection of Good Drive

Warning: Ejecting a physical disk that is currently operating risks damaging the physical disk, it's controller, interface, the node's storage back-plane and/or the RAID controller. Never eject a running drive! We do it here using a test node and we accepted the risk of damaging the hardware.

There are numerous reasons why a perfectly good drive might get ejected from a node. In spite of the risks in the above warning, people often seem to eject a running disk. Perhaps out of ignorance, or out of a desire to simulate a failure. In any case, it happens and it is important to know how to recover from it.

As we discussed above, ejecting a disk will cause it to vanish from the list of physical disks and the logical disk it was in will become degraded.

Once re-inserted, the disk will be flagged as 'Unconfigured(bad)'. In this case, you know the disk is fine, so marking it as good after reinserting it is fine.

Please jump up to that section to finish recovering the physical disk.

Pre-Failure Drive Replacement

With the AN!CDB monitoring program, you may occasionally get an alert like:

Still healthy drive:
RAID 0's Physical Disk 5's "Other Error Count" has changed!
  0	-> 1

This is not always a concern. For example, every drive has a rated "unrecoverable read error (URE)" rating, usually 1 in every 10^15 reads for enterprise SAS drives. When the logical disk is healthy, the read error will not be a problem as the read can be recovered and the drive itself is still fine.

However, if we see a sudden spike in "Other Error Count", it may be a good idea to replace the drive.

A disk that may be failing and should be replaced:
RAID 0's Physical Disk 3's "Other Error Count" has changed!
  0	-> 4

In this case, we see that four errors occurred at almost the same time. This causes concern and warrants a pre-failure replacement.

In this case, you would leave the questionable disk in the logical disk until the replacement drive is in-hand. Once we're ready, we will remove the drive from the logical disk, which will leave it ready to eject, and then insert the replacement physical disk.

(Simulated) "Other" Error Count showing 4 errors. "Remove from Logical Disk" highlighted.

When you click on 'Remove from Logical Disk', you will be asked to confirm the action. You will also be warned that this action will degrade the logical disk. In this case, the replacement drive is ready to insert, so we are safe to proceed.

Confirming the "Remove from Logical Disk" action.

Click on 'Confirm', the physical disk will be taken offline, marked as missing and then spun down. Once completed, you will be able to safely eject the physical disk and install the replacement drive.

Physical disk out of the logical disk and is safe to remove.

When you insert the replacement disk, it should automatically be added to the logical disk and the rebuild should begin.

Note: If the freshly inserted drive is not automatically added to the logical disk, please see the "Inserting a Replacement Physical Disk" section above.
Replacement physical disk inserted and rebuild begun.

Done!

Managing Hot-Spares

In this final section, we will add a "Hot-Spare" drive to our node.

A "Hot-Spare" is an unused drive that the RAID controller knows can be used to immediately replace a failed drive. This is a popular option for people who want to return to a fully redundant state as soon after a failure as possible.

We will Configure a Hot-Spare, show how it replaces a failed drive, and show how to unmark a drive as a hot-spare, in case the Hot-Spare itself goes bad.

Creating a Hot-Spare

Up until this point, we've had four physical disks in our system. Here, we've inserted a fifth healthy disk. The logical disk is Optimal, so no default action was take. Likewise, no option to add the physical disk to a logical disk is presented.

Newly inserted physical disk.

The one option that is presented, however, is 'Make Hot-Spare'.

New physical disk with 'Make Hot-Spare' highlighted.

Once marked as a hot-spare, the disk will be automatically used to replace a physical drive, should one of an equal or smaller size fail.

Physical disk now marked as a 'Hot-Spare, Spun up'.

Done!

Now any disk failure will recover as fast as technically possible.

Example of a Hot-Spare Working

As we saw earlier, there are many ways for a logical disk to degrade. The hot-spare will be used automatically as soon as the array is degraded, regardless of the cause.

For this reason, we'll simply remove a physical disk currently in the logical disk. We should see immediately that the hot-spare has entered the array and rebuild has begun.

I will remove physical disk '[252:6]' from the array.

Physical disk '[252:6]' removed from the logical disk, former hot-spare physical disk '[252:5]' already in the logical disk and rebuilding.

At this point, we could eject [252:6] or spin it back up. I know it's healthy, so I will spin it up and mark it as a hot spare in preparation for the next section.

Replacing a Failing Hot-Spare

As we discussed earlier, a drive may show signs of failing before it's actually failed. Of course, it could just as well die and get marked as Unconfigured(bad) or vanish entirely.

In this case, we'll pretend the drive is predicted to fail.

To do this, simply click on 'Unmark as Hot-Spare'.

Hot-spare physical disk's 'Unmark as Hot-Spare' highlighted.



 

Any questions, feedback, advice, complaints or meanderings are welcome.